Linde MPR-01 pumps

Open circuit pump
Regulating pump
Designed for medium pressures

Specifications:
Pressures
Maximum pressure
350 bar
Nominal pressure
280 bar
Continuous pressure
210 bar
Permissible housing pressure
1,5 bar


Model MPR-01
Rated size
28
45
71
Displacment [cc]
28
45
71
Maximum speed at Vg max  [rpm]
3000
2600
2200
Maximum power [kW]
39*
55*
73*
Moment of inertia[kgm2]
0,0017
0,0033
0,0083
Rotation
cw and ccw
* Theoretical values
sizes
Rated sizes
28
45
71
Weights [kg]
15
21
33
Shaft profile
Ansi B92.1
16/32, 13t
16/32, 15t
12/24, 14t
Flange profile [SAE]

(101,6 mm)
B - B
(101,6 mm)

(127 mm)
Port profile, Pressure port [SAE 6000 psi]
¾"
1"
1"
Poprt profile, Suction port [SAE 3000 psi]
1¼"
1½"
2"

Features
Controls
Compact design
LS Loadsensing with pressure cut off
Optional PTO
Pressure regulated
Tandem configuration possible
Flow regulated